查看温度 hpasmcli -s "show temp"
查看风扇 hpasmcli -s 'show fans'
查看电源模块 hpasmcli -s "show powersupply"
查看机器型号,序列号,CPU,内存大小 hpasmcli -s "show server"
查看控制器状态 hpacucli ctrl all show status
查看硬盘状态 hpacucli ctrl slot=0 pd all show status
查看硬盘RAID hpacucli controller slot=0 logicaldrive all show
• 控制器命令:
hpacucli> ctrl all show config ## Display detail of Controller
hpacucli> ctrl all show config detail
hpacucli> ctrl all show status ## Display status of Controller
hpacucli> ctrl slot=0 modify dwc=disable ## Enable or Disable the cache
hpacucli> ctrl slot=0 modify dwc=enable
hpacucli> rescan ## Detects newly added devices since the last rescan
• 物理驱动器命令:
hpacucli> ctrl slot=0 pd all show ## Display detail information of PhysicalDrive hpacucli> ctrl slot=0 pd 2:3 show detail
hpacucli> ctrl slot=0 pd all show status ## Display Status of physicalDrive hpacucli> ctrl slot=0 pd 2:3 show status
hpacucli> ctrl slot=0 pd 2:3 modify erase ## To Erase the physicalDrive
hpacucli> ctrl slot=0 pd 2:3 modify led=on ## To enable or Disable the LED hpacucli> ctrl slot=0 pd 2:3 modify led=off
• 逻辑驱动器命令:
hpacucli> ctrl slot=0 ld all show ## Display detail information of LogicalDrive hpacucli> ctrl slot=0 ld 4 show
hpacucli> ctrl slot=0 ld all show status ## Display Status of LogicalDrive hpacucli> ctrl slot=0 ld 4 show status
hpacucli> ctrl slot=0 ld 4 modify reenable forced ## To re-enabling failed drive
配置 RAID 等级:
•使用一个驱动器用 RAID 0 来创建逻辑磁盘:
hpacucli> ctrl slot=0 create type=ld drives=1:12 raid=0
•使用两个驱动器用 RAID 1 来创建逻辑磁盘:
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14 size=300 raid=1
•使用五个驱动器用 RAID 5 来创建逻辑磁盘:
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14,1:15,1:16,1:17 raid=5
•展开、扩展和添加备件并删除当前 RAID 中的逻辑驱动器:
hpacucli> ctrl slot=0 ld 4 delete
## To Delete LogicalDrives
hpacucli> ctrl slot=0 ld 4 add drives=2:3
## Expanding ld by adding one more drive
hpacucli> ctrl slot=0 ld 4 modify size=500 forced
## Extending the LogicalDrives
hpacucli> ctrl slot=0 array all add spares=1:5,1:7
## Add two Spare disks